Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Am Heart J ; 265: 50-58, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37479162

RESUMO

BACKGROUND: Despite high blood pressure being the leading preventable risk factor for death, only 1 in 3 patients achieve target blood pressure control. Key contributors to this problem are clinical inertia and uncertainties in relying on clinic blood pressure measurements to make treatment decisions. METHODS: The NEXTGEN-BP open-label, multicenter, randomized controlled trial will investigate the efficacy, safety, acceptability and cost-effectiveness of a wearable blood pressure monitor-based care strategy for the treatment of hypertension, compared to usual care, in lowering clinic blood pressure over 12 months. NEXTGEN-BP will enroll 600 adults with high blood pressure, treated with 0 to 2 antihypertensive medications. Participants attending primary care practices in Australia will be randomized 1:1 to the intervention of a wearable-based remote care strategy or to usual care. Participants in the intervention arm will undergo continuous blood pressure monitoring using a wrist-wearable cuffless device (Aktiia, Switzerland) and participate in 2 telehealth consultations with their primary care practitioner (general practitioner [GP]) at months 1 and 2. Antihypertensive medication will be up-titrated by the primary care practitioner at the time of telehealth consults should the percentage of daytime blood pressure at target over the past week be <90%, if clinically tolerated. Participants in the usual care arm will have primary care consultations according to usual practice. The primary outcome is the difference between intervention and control in change in clinic systolic blood pressure from baseline to 12 months. Secondary outcomes will be assessed at month 3 and month 12, and include acceptability to patients and practitioners, cost-effectiveness, safety, medication adherence and patient engagement. CONCLUSIONS: NEXTGEN-BP will provide evidence for the effectiveness and safety of a new paradigm of wearable cuffless monitoring in the management of high blood pressure in primary care. TRIAL REGISTRATION: ACTRN12622001583730.


Assuntos
Hipertensão , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Pressão Sanguínea/fisiologia , Anti-Hipertensivos/uso terapêutico , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Atenção Primária à Saúde/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
2.
Int J Stroke ; 17(10): 1156-1162, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34994269

RESUMO

BACKGROUND: Patients who suffer intracerebral hemorrhage (ICH) are at very high risk of recurrent ICH and other serious cardiovascular events. A single-pill combination (SPC) of blood pressure (BP) lowering drugs offers a potentially powerful but simple strategy to optimize secondary prevention. OBJECTIVES: The Triple Therapy Prevention of Recurrent Intracerebral Disease Events Trial (TRIDENT) aims to determine the effects of a novel SPC "Triple Pill," three generic antihypertensive drugs with demonstrated efficacy and complementary mechanisms of action at half standard dose (telmisartan 20 mg, amlodipine 2.5 mg, and indapamide 1.25 mg), with placebo for the prevention of recurrent stroke, cardiovascular events, and cognitive impairment after ICH. DESIGN: An international, double-blind, placebo-controlled, randomized trial in adults with ICH and mild-moderate hypertension (systolic BP: 130-160 mmHg), who are not taking any Triple Pill component drug at greater than half-dose. A total of 1500 randomized patients provide 90% power to detect a hazard ratio of 0.5, over an average follow-up of 3 years, according to a total primary event rate (any stroke) of 12% in the control arm and other assumptions. Secondary outcomes include recurrent ICH, cardiovascular events, and safety. RESULTS: Recruitment started 28 September 2017. Up to 31 October 2021, 821 patients were randomized at 54 active sites in 10 countries. Triple Pill adherence after 30 months is 86%. The required sample size should be achieved by 2024. CONCLUSION: Low-dose Triple Pill BP lowering could improve long-term outcome from ICH.


Assuntos
Acidente Vascular Cerebral , Humanos , Adulto , Hemorragia Cerebral , Anti-Hipertensivos/uso terapêutico , Doença Crônica , Infarto Cerebral
3.
Diabetes care ; 43(8): 1859-1867, Aug., 2020.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1128179

RESUMO

OBJECTIVE: Despite evidence of a relationship among obstructive sleep apnea (OSA), metabolic dysregulation, and diabetes, it is uncertain whether OSA treatment can improve metabolic parameters. We sought to determine effects of long-term continuous positive airway pressure (CPAP) treatment on glycemic control and diabetes risk in patients with cardiovascular disease (CVD) and OSA. RESEARCH DESIGN AND METHODS: Blood, medical history, and personal data were collected in a substudy of 888 participants in the Sleep Apnea cardioVascular Endpoints (SAVE) trial in which patients with OSA and stable CVD were randomized to receive CPAP plus usual care, or usual care alone. Serum glucose and glycated hemoglobin A1c (HbA1c) were measured at baseline, 6 months, and 2 and 4 years and incident diabetes diagnoses recorded. RESULTS: Median follow-up was 4.3 years. In those with preexisting diabetes (n = 274), there was no significant difference between the CPAP and usual care groups in serum glucose, HbA1c, or antidiabetic medications during follow-up. There were also no significant between-group differences in participants with prediabetes (n = 452) or new diagnoses of diabetes. Interaction testing suggested that women with diabetes did poorly in the usual care group, while their counterparts on CPAP therapy remained stable. CONCLUSIONS: Among patients with established CVD and OSA, we found no evidence that CPAP therapy over several years affects glycemic control in those with diabetes or prediabetes or diabetes risk over standard-of-care treatment. The potential differential effect according to sex deserves further investigation.


Assuntos
Glicemia/metabolismo , Pressão Positiva Contínua nas Vias Aéreas , Hemoglobinas Glicadas/metabolismo , Comorbidade , Apneia Obstrutiva do Sono/diagnóstico , Complicações do Diabetes , Diabetes Mellitus Tipo 2
4.
Diabetes Care ; 43(8): 1859-1867, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32291275

RESUMO

OBJECTIVE: Despite evidence of a relationship among obstructive sleep apnea (OSA), metabolic dysregulation, and diabetes, it is uncertain whether OSA treatment can improve metabolic parameters. We sought to determine effects of long-term continuous positive airway pressure (CPAP) treatment on glycemic control and diabetes risk in patients with cardiovascular disease (CVD) and OSA. RESEARCH DESIGN AND METHODS: Blood, medical history, and personal data were collected in a substudy of 888 participants in the Sleep Apnea cardioVascular Endpoints (SAVE) trial in which patients with OSA and stable CVD were randomized to receive CPAP plus usual care, or usual care alone. Serum glucose and glycated hemoglobin A1c (HbA1c) were measured at baseline, 6 months, and 2 and 4 years and incident diabetes diagnoses recorded. RESULTS: Median follow-up was 4.3 years. In those with preexisting diabetes (n = 274), there was no significant difference between the CPAP and usual care groups in serum glucose, HbA1c, or antidiabetic medications during follow-up. There were also no significant between-group differences in participants with prediabetes (n = 452) or new diagnoses of diabetes. Interaction testing suggested that women with diabetes did poorly in the usual care group, while their counterparts on CPAP therapy remained stable. CONCLUSIONS: Among patients with established CVD and OSA, we found no evidence that CPAP therapy over several years affects glycemic control in those with diabetes or prediabetes or diabetes risk over standard-of-care treatment. The potential differential effect according to sex deserves further investigation.


Assuntos
Glicemia/metabolismo , Doenças Cardiovasculares/terapia , Pressão Positiva Contínua nas Vias Aéreas , Diabetes Mellitus Tipo 2/etiologia , Apneia Obstrutiva do Sono/terapia , Idoso , Glicemia/análise , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/epidemiologia , Comorbidade , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/terapia , Feminino , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/metabolismo , Controle Glicêmico , Humanos , Masculino , Pessoa de Meia-Idade , Estado Pré-Diabético/sangue , Estado Pré-Diabético/epidemiologia , Estado Pré-Diabético/etiologia , Estado Pré-Diabético/terapia , Fatores de Risco , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Padrão de Cuidado , Cooperação e Adesão ao Tratamento/estatística & dados numéricos
5.
Sleep ; 42(10)2019 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-31587046

RESUMO

STUDY OBJECTIVES: Poor adherence to continuous positive airway pressure (CPAP) commonly affects therapeutic response in obstructive sleep apnea (OSA). We aimed to determine predictors of adherence to CPAP among participants of the Sleep Apnea and cardioVascular Endpoints (SAVE) trial. METHODS: SAVE was an international, randomized, open trial of CPAP plus usual care versus usual care (UC) alone in participants (45-75 years) with co-occurring moderate-to-severe OSA (≥12 episodes/h of ≥4% oxygen desaturation) and established cardiovascular (CV) disease. Baseline sociodemographic, health and lifestyle factors, OSA symptoms, and 1-month change in daytime sleepiness, as well as CPAP side effects and adherence (during sham screening, titration week, and in the first month), were entered in univariate linear regression analyses to identify predictors of CPAP adherence at 24 months. Variables with p <0.2 were assessed for inclusion in a multivariate linear mixed model with country, age, and sex included a priori and site as a random effect. RESULTS: Significant univariate predictors of adherence at 24 months in 1,121 participants included: early adherence measures, improvement in daytime sleepiness at 1 month, fixed CPAP pressure, some measures of OSA severity, cardiovascular disease history, breathing pauses, and very loud snoring. While observed adherence varied between countries, adherence during sham screening, initial titration, and the first month of treatment retained independent predictive value in the multivariate model along with fixed CPAP pressure and very loud snoring. CONCLUSIONS: Early CPAP adherence had the greatest predictive value for identifying those at highest risk of non-adherence to long-term CPAP therapy. CLINICAL TRIAL REGISTRATION: SAVE is registered with clinicaltrials.gov (NCT00738179).


Assuntos
Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/terapia , Pressão Positiva Contínua nas Vias Aéreas/tendências , Cooperação do Paciente , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/terapia , Idoso , Doenças Cardiovasculares/fisiopatologia , Pressão Positiva Contínua nas Vias Aéreas/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Apneia Obstrutiva do Sono/fisiopatologia , Ronco/epidemiologia , Ronco/fisiopatologia , Ronco/terapia , Fatores de Tempo
6.
Am J Respir Crit Care Med ; 196(11): 1456-1462, 2017 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-28743190

RESUMO

RATIONALE: Obstructive sleep apnea (OSA) is associated with impaired renal function, but uncertainty exists over whether OSA treatment can influence renal outcomes. OBJECTIVES: To determine the effects of continuous positive airway pressure (CPAP) on renal function in subjects with coexisting OSA and cardiovascular disease. METHODS: This was a substudy of the international SAVE (Sleep Apnea Cardiovascular Endpoints) trial, in which 2,717 patients with moderate to severe OSA and established coronary or cerebrovascular disease were randomized to receive either CPAP plus usual care or usual care alone. Renal function and adverse renal events were compared between the CPAP (n = 102) and usual care (n = 98) groups. Glomerular filtration rate was estimated at randomization and at the end of follow-up, and the urinary albumin-to-creatinine ratio was measured at study exit. MEASUREMENTS AND MAIN RESULTS: In 200 substudy participants (mean age, 64 yr; median, 4% oxygen desaturation index; 20 events/h; mean estimated glomerular filtration rate at baseline, 82 ml/min/1.73 m2), the median (interquartile range) changes in estimated glomerular filtration rate (ml/min/1.73 m2/yr) were -1.64 (-3.45 to -0.740) in the CPAP group and -2.30 (-4.53 to -0.71) in the usual care group (P = 0.21) after a median of 4.4 years. There were no between-group differences in end-of-study urinary albumin-to-creatinine ratio or in the occurrence of serious renal or urinary adverse events during the trial. The level of CPAP adherence did not influence the findings. CONCLUSIONS: CPAP treatment of OSA in patients with cardiovascular disease does not alter renal function or the occurrence of renal adverse events. Clinical trial registered with www.clinicaltrials.gov (NCT00738179).


Assuntos
Doenças Cardiovasculares/complicações , Pressão Positiva Contínua nas Vias Aéreas/métodos , Rim/fisiopatologia , Insuficiência Renal Crônica/complicações , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/terapia , Idoso , Doenças Cardiovasculares/fisiopatologia , Feminino , Humanos , Testes de Função Renal/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/fisiopatologia
7.
Res Nurs Health ; 40(3): 197-205, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28297072

RESUMO

Frontline nurses encounter operational failures (OFs), or breakdowns in system processes, that hinder care, erode quality, and threaten patient safety. Previous research has relied on external observers to identify OFs; nurses have been passive participants in the identification of system failures that impede their ability to deliver safe and effective care. To better understand frontline nurses' direct experiences with OFs in hospitals, we conducted a multi-site study within a national research network to describe the rate and categories of OFs detected by nurses as they provided direct patient care. Data were collected by 774 nurses working in 67 adult and pediatric medical-surgical units in 23 hospitals. Nurses systematically recorded data about OFs encountered during 10 work shifts over a 20-day period. In total, nurses reported 27,298 OFs over 4,497 shifts, a rate of 6.07 OFs per shift. The highest rate of failures occurred in the category of Equipment/Supplies, and the lowest rate occurred in the category of Physical Unit/Layout. No differences in OF rate were detected based on hospital size, teaching status, or unit type. Given the scale of this study, we conclude that OFs are frequent and varied across system processes, and that organizations may readily obtain crucial information about OFs from frontline nurses. Nurses' detection of OFs could provide organizations with rich, real-time information about system operations to improve organizational reliability. © 2017 Wiley Periodicals, Inc.


Assuntos
Eficiência Organizacional , Falha de Equipamento/estatística & dados numéricos , Recursos Humanos de Enfermagem no Hospital/organização & administração , Melhoria de Qualidade , Cuidados Críticos , Estudos Transversais , Humanos , Enfermagem Médico-Cirúrgica/organização & administração , Enfermeiras e Enfermeiros , Recursos Humanos de Enfermagem no Hospital/educação , Segurança do Paciente , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...